Trolley color doppler Ultrasound Diagnostic System
1: | Summary of main specifications and system of cart type color Doppler ultrasound |
1.1 | Trolley type all digital color Doppler ultrasonic mainframe |
1.2 | Ultrasonic host operating system: Windows operating system |
1.3 | Applications: Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal |
1.4 | Probes: Convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, Cardiac probe,4D Volume probe |
1.5 | Applications and report: Abdominal,OB,GYN,Cardiac,Urinary,Small Parts,Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc. |
☆1.6 | carotid artery intima measurement thickness(IMT) |
☆1.7 | Automatic spectral envelope measurement |
1.8 | Full digital transmission and reception of beam synthesizer |
1.9 | Color Doppler imaging(C) |
1.10 | Pulse Doppler Imaging(PW) |
☆1.12 | Coherent Contrast imaging(CCI) |
1.12 | Continuous wave Doppler imaging(CW) |
☆1.13 | B/C/D Real-time three synchronous imaging |
☆1.14 | Power Doppler imaging(PDI) |
☆1.15 | Direct power Doppler imaging(DPDI) |
1.16 | M mode imaging |
☆1.17 | Anatomic M mode imaging |
☆1.18 | Color Doppler M mode imaging |
☆1.19 | Elastography |
☆1.20 | Tissue Doppler imaging(TDI) |
☆1.21 | Strain rate imaging (SRI) |
1.22 | Tissue harmonic imaging(THI) |
1.23 | Fusion harmonic imaging(FHI) |
1.24 | Speckle Reduce imaging(SRI) |
☆1.25 | Panoramic imaging |
☆1.26 | Deflection imaging |
☆1.27 | Trapezoidal imaging |
1.28 | Adaptive velocity optimization |
☆1.29 | Free hand 3D |
1.30 | Real time 3D imaging(3D/4D) |
1.31 | DICOM3.0 |
1.32 | Monitor:≥19 inch,high definition ultrasonic display |
1.33 | ≥10 inch touch screen |
1.34 | Physical clipboard: save the image on the left side of the screen, which can be directly saved or deleted. |
1.35 | The system has the function of on-the-spot upgrade |
1.36 | Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation. |
1.37 | Probe interface: 4 |
1.38 | Chinese and English System, Chinese and English input, optional |
1.39 | Depth:≥360mm; |
1.40 | Extended imaging |
2: | Probes |
2.1 Convex probe | Fundamental Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz, Harmonic Frequency: 4.0MHz/4.6MHz/5.0MHz, |
2.2 Linear probe | Fundamental Frequency:4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz, Harmonic Frequency: 8.0MHz/9.2MHz/10.0MHz, |
2.3 Trans-vaginal probe | Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
2.4 Micro-convex probe | Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
2.5 Cardiac probe | Fundamental Frequency:1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz, Harmonic Frequency: 3.4MHz/3.8MHz/4.2MHz, |
2.6 4D Volume probe | Fundamental Frequency: 2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz, Harmonic Frequency: 4.0MHz/5.0MHz/6.0MHz, |
3: | 2D imaging mode |
3.1 | Gain:0-100,Step 2 adjustable |
3.2 | TGC:8 segment adjustable |
3.3 | Maximum focus point:≥7, which can be moved throughout the whole process. |
3.4 | Speckle reduction:0-5,5 level |
3.5 | Space Synthesis:0-2,2 level(Liner probe: 3 level, cardiac probe:0) |
3.6 | Dynamic:30-180,35 level,step 5 adjustable |
3.7 | Line density:low、middle、high,3 level |
3.8 | Frame correlation:0-4,4 level |
3.9 | Noise reduction:0-5,5 level |
3.10 | Edge Enhancement:0-5,5 level |
3.11 | Sound power:2-10, 9 level |
3.12 | Grey scale:0-67, 67 level |
3.13 | False color:0-67,67 level |
3.14 | Image style:Soft-Comparison,2 level |
|